Boiler mounting

 Boiler mounting: 

1. Pressure gauge

2. Feed check valve

3. Water level indicator

4. Stream stop valve 

5. Fusible plug

Above all  devices mounting on the boiler 

Pressure gauge : 

It is measure the pressure of stream so it is show the quality of stream. high  pressure stream is supersaturated stream and low pressure stream is saturated stream. 

Feed check valve  :  

It is measure the quality of water available on the boiler which is help  prevent to damage of Of tube   because of tube will damage due to high temperatures. 

Water level Indicator :  

It is measure the level of water in the boiler it is fitted between stream and water portions  . 

Stream stop valve : 

It is control the stream of boiler. 

Fusible plug: 

It is a safety device which prevent the blast of boiler because Of maintain the pressure of stream. It  is release the high pressure of  stream by fusing material (low temperature material used Zn , ti etc ) 


Thanks